Analysis of regeneration temperature control technology of carbon molecular sieve in nitrogen generator
Nitrogen generator is the core equipment to obtain high purity nitrogen in the industrial field. Its core process-pressure swing adsorption (PSA) relies on the selective adsorption capacity of carbon molecular sieve to separate oxygen and nitrogen. The adsorption activity of carbon molecular sieve is not recovered by regeneration process, and the precise control of regeneration temperature is the key link to determine the regeneration effect, the life of molecular sieve and the quality of nitrogen. In this paper, the control principle, influencing factors, methods and matters needing attention of the regeneration temperature of carbon molecular sieve are analyzed.
First, the core principle of regeneration temperature control
The adsorption performance of carbon molecular sieves is affected by the synergy of pressure and temperature: at high pressure (0.6-1.0 mpa) , its adsorption capacity for oxygen is much higher than that of nitrogen; while at low pressure (0.02-0.05 mpa) or vacuum state, the adsorption capacity of carbon molecular sieves is much higher than that of nitrogen, the adsorption capacity of oxygen drops sharply, and the temperature rise can further promote the oxygen molecules to escape from the micropores of the molecular sieve. The mechanism of temperature action is that increasing temperature enhances the thermal motion energy of the molecules, so that the adsorbed oxygen molecules overcome the van der Waals force on the surface of the molecular sieve and complete the desorption. However, the thermal stability of carbon molecular sieve is limited. Too high temperature will destroy its microporous structure (such as microporous collapse, surface area reduction) , resulting in a decrease in adsorption capacity.
II. Key influencing factors of regeneration temperature
Characteristics of carbon molecular sieves
The thermal stability of different types of carbon molecular sieves is significantly different: the upper limit of regeneration temperature of conventional commercial carbon molecular sieve is 150 °C, and the high temperature resistant type can withstand 160-180 °C, but the technical parameters of the product should be taken as the basis. For example, molecular sieves designed for high-humidity feed gases need to be regenerated at slightly higher temperatures than conventional models to ensure complete moisture desorption.
2. Feed gas quality
The water, oil and organic impurities in the feed gas will adhere to the surface of the molecular sieve, which will increase the difficulty of desorption. If the relative humidity of the feed gas is higher than 80% , the regeneration temperature should be raised to 120-130 °C. if there is a small amount of oil, the regeneration temperature should be further raised to about 140 °C to avoid the“Molecular sieve poisoning” caused by impurity accumulation.
3. Regeneration pressure
The lower the regeneration pressure (such as vacuum regeneration) , the lower the temperature required for oxygen desorption. If the regeneration pressure is higher than 0.05 MPA, the inhibition effect of temperature compensation pressure on desorption needs to be improved.
4. Regeneration cycle
Temperature is inversely proportional to regeneration time: 3 Min at 120 °C and 5 min at 100 °C can achieve similar results, but the former consumes more energy. The efficiency and cost should be balanced according to the production rhythm.
Control method of regeneration temperature
1. Heating medium and method
Product nitrogen is usually used as regeneration gas (to avoid the introduction of impurities) , through the electric heater or steam heater after heating into the tower to be regenerated. The heater should have the ability of precise temperature control, and the error should be controlled within ± 5 °C.
2. Temperature monitoring and feedback
Thermocouples are installed at the inlet and outlet of the regeneration tower: the inlet temperature is used to adjust the heater power, and the outlet temperature reflects the regeneration progress (regeneration is completed when the outlet temperature is stabilized at the set value) . For example, the inlet temperature is set at 120 °C, and the outlet temperature should be above 115 °C to ensure uniform regeneration of the bed.
3. Automatic control system
PID (proportional-integral-differential) control is adopted: the output of the heater is automatically adjusted according to the set temperature, and the temperature and pressure coordinated control is realized by combining the pressure sensor data. For example, when the regeneration pressure increases, the system automatically raises the heating temperature to maintain desorption efficiency.
4. Stepwise heating strategy
In view of the complex feed gas, the step heating is adopted: firstly, the oxygen is desorbed at 80-100 °C, then the moisture/impurity is desorbed at 120-140 °C, and finally the temperature is reduced to room temperature to reduce the thermal damage of molecular sieve.